AFT053 Fundamentals of Temperature Measurement Educational Training Equipment Demonstrator Thermal Laboratory Equipment1 Description
1. Equipment introduction
1.1 Overview
AFT053 temperature measurement and calibration unit is a practical training device for measuring and calibrating temperature. The device provides PT100 temperature measurement module, NTC temperature measurement module, K-type temperature measurement module,mercury thermometer measurement module, pressure temperature measurement module, bimetal temperature module and wet and dry bulb thermometer module. Through these modules, the device can cover most temperature measurement experiments. For the electrical temperature measurement module, the device provides a variety of precision resistors for calibration comparison.
1.2 Features
(1) The AFT053 temperature measurement calibration unit adopts a safe electrical layout and is grounded safely and reliably.
(2) The AFT053 temperature measurement calibration unit adopts a modular design, and each unit can operate independently, greatly increasing the type and quantity of experiments.
(3) The AFT053 temperature measurement calibration unit provides a port for the electrical temperature measurement device, and the user can directly obtain the analog parameters of the temperature.
2. Technical parameters
Input power supply: Input power supply: single-phase single-wire 240V+/- 10% 50Hz
Weight:67kg
Size: 980mm*780mm*950mm
Working conditions: Ambient temperature 10℃~30℃ Relative humidity <75% (25℃)

3. Components list and detailed introduction
3.1 Main part
No Name
1 NTC temperature sensor display instrument
2 PT100 temperature sensor display instrument
3 Wet and dry bulb thermometer
4 Electric stove with heating kettle
5 K type temperature sensor display instrument
6 pressure thermometer
7 bimetallic thermometer
8 Mercury thermometer 1
9 Mercury thermometer 2
10 Thermos bucket
11 digital multimeter
12 heater
13 PT100 temperature sensor
14 K type temperature sensor
15 AC220V output power socket
16 NTC temperature sensor
3.2 Equipment configuration list
No Name Qty
Component 1 NTC temperature sensor 1
Component 2 PT100 temperature sensor 1
Component 3 K type temperature sensor 1
Component 4 heater 1
Component 5 Mercury thermometer 1
Component 6 Thermos bucket 1
Component 7 pressure thermometer 1
Component 8 bimetallic thermometer 1
Component 9 Wet and dry bulb thermometer 1
Component 10 Electric stove with heating kettle 1
3.3 Accessories
No Name Qty
1 power cable 1
2 heater 1
3 Red K4 test line 4
4 Black K4 test line 4
5 Fuse 5
6 temperature test paper 7
7 K type thermometer 1
8 NTC type thermometer 1
9 PT100 type thermometer 1
10 K type thermometer plug adapter cable 1
11 digital multimeter 1
12 toolbox 1
4. Experiment list
Experiment 1 Understand the principle of temperature measurement calibration
Experiment 2 Understand the use of PT100 temperature measurement unit module
Experiment 3 Understand the use of NTC temperature measurement unit module
Experiment 4 Understand the use of K-type temperature measurement unit module
Experiment 5 Understand the use of mercury thermometer measurement unit module
Experiment 6 Understand the use of pressure temperature measurement unit module
Experiment 7 Understand the use of bimetallic temperature measurement unit module
Experiment 8 Understand the use of dry and wet bulb thermometer measurement unit modules